SW2 DIP Switch and LED1-8 bar LEDs on the HES7XV690-4000BP Board

Introduction

This application note describes all of the possible configurations of the S2 DIP switch that is available for Diagnostic Design that is delivered with the HES7XV690-4000BP board.

The following sections also present status codes that are available on the LED1-8 bar LED indicators.

HES7XV690-4000BP S2 DIP switch description

Figure 1 S2 DIP Switch location

Figure 2 S2 DIP Switch orientation

Table 1: S2 DIP Switch Description Table

DIP Switch position

Function

Description

POS1

HARD RESET

Turning On this switch causes loss of FPGA0-2 configurations

POS2

USER RESET

Turning ON this switch causes a reset of the user designs in the FPGA0-2 chips

POS3

Bar LEDs status selector

POS3-5 switches between statuses from FPGA0, FPGA1, FPGA2, PLLs, and the master status from Diagnostic Design

POS4

POS5

POS6

PLLs control selector

Selects PLLs control master between the USB program and Diagnostic Design

POS7

PLLs conf. selector

Switches between PLLs configuration type (High/Low speed) that is intended for Diagnostic Design

POS8

PLLs Reset

PLLs chip reset - must be issued after configuration or PLLs selector change

S2 DIP Switch Configuration Tables

Table 2: S2 DIP Switch, POS1 Configuration Table

POS1

Description

ON

HARD RESET active - FPGA0-2 lost their configurations

OFF (default)

HARD RESET inactive - normal operations

Table 3: S2 DIP Switch, POS2 Configuration Table

POS2

Description

ON

USER RESET active- reset signal for test design located in FPGA0-2

OFF (default)

USER RESET inactive - normal operations

Table 4: S2 DIP Switch, POS3-5 Configuration Table

POS3

POS4

POS5

Description

ON

ON

ON

Eight user statuses from FPGA0

OFF

ON

ON

Eight user statuses from FPGA1

ON

OFF

ON

Eight user statuses from FPGA2

OFF

OFF

ON

Six statuses from PLLs SI5326 - locked signals

ON

ON

OFF

Six statuses from I2C configuration module - error NACK signals

OFF

ON

OFF

Three statuses of DONE signals from FPGAs

OFF

OFF

OFF

Five statuses from Diagnostic Design

(default)

Table 5: S2 DIP Switch, POS6 Configuration Table

POS6

Description

ON

PLL control from USB program

OFF (default)

Internal PLL control from Diagnostic Design

Table 6: S2 DIP Switch, POS7 Configuration Table

POS7

Description

ON

PLL internal configuration1 – used for High Speed Diagnostic design

OFF (default)

PLL internal configuration2 – used for Low Speed Diagnostic design

Table 7: S2 DIP Switch, POS8 Configuration Table

POS8

Description

ON

PLL Reset active

OFF (default)

PLL Reset inactive

LED1-8 Status Bar LEDs Description

Figure 3 LED1-8 status bar LEDs location

Figure 4 LED1-8 bar LEDs indicators

Diagnostic Design LED1-8 Bar LEDs statuses

Table 8: Bar LEDs status for Diagnostic Design Test (POS3, POS4, POS5=OFF, OFF, OFF)

Description

LED

Description

Clocking test succeeded (when ON)

LED1

LED5

Empty

Interconnections test succeeded (when ON)

LED2

LED6

Empty

GTX/GTH test succeeded (when ON)

LED3

LED7

Empty

Memory test succeeded (when ON)

LED4

LED8

Diagnostic Design is working (when blink)

Table 9: Default S2 DIP Switch Settings for Diagnostic Design Test

POS1

POS2

POS3

POS4

POS5

POS6

POS7

POS8

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

Table 10: Default LED1-8 Bar LEDs Statuses for FPGA2 Test

State

LED

State

ON

LED1

LED5

OFF

ON

LED2

LED6

OFF

ON

LED3

LED7

OFF

ON

LED4

LED8

Blink

Diagnostic Design tests description:

  • Memory test - SO-DIM memories test

  • GTX/GTH test - all GTX/GTH connections test

  • Interconnections test - all IO interconnections (all available connections between FPGA0-2) test

  • Clocking test - clock module and clock lines test

NOTE: The Diagnostic test takes about 30 seconds and is signalized by the blinking of LED8

LED1-8 Bar LEDs statuses for FPGA0

Table 11: Bar LEDs status for FPGA0 (POS3, POS4, POS5=ON, ON, ON)

Description

LED

Description

REF clk present (when BLINK)

LED1

LED5

GTX from FPGA1 to FPGA0 fail (when ON)

Clock test fail (when ON)

LED2

LED6

Empty

LVDS from FPGA1 to FPGA0 fail (when ON)

LED3

LED7

DDR status1*

Common bus fail (when ON)

LED4

LED8

DDR status2*

*refer to Table 12: DDR status1-2

Table 12: DDR Status1-2

DDR status1

DDR status2

Description

OFF

OFF

no errors

OFF

ON

Incorrect SO-DIMM module for the test (SPD parameters not valid)

ON

OFF

Calibration failed

ON

ON

Data error present

Table 13: Default S2 DIP Switch Settings for FPGA0 Test

POS1

POS2

POS3

POS4

POS5

POS6

POS7

POS8

OFF

OFF

ON

ON

ON

OFF

OFF

OFF

Table 14: Default LED1-8 bar LEDs statuses for FPGA2 Test

State

LED

State

BLINK

LED1

LED5

OFF

OFF

LED2

LED6

OFF

OFF

LED3

LED7

OFF

OFF

LED4

LED8

OFF

LED1-8 Bar LEDs Statuses for FPGA1

Table 15: Bar LEDs status for FPGA1 (POS3, POS4, POS5=OFF, ON, ON)

Description

LED

Description

REF clk present (when BLINK)

LED1

LED5

GTX from FPGA0 to FPGA1 fail (when ON)

Clock test fail (when ON)

LED2

LED6

GTX from FPGA2 to FPGA1 fail (when ON)

LVDS from FPGA0 to FPGA1 fail (when ON)

LED3

LED7

DDR status1*

LVDS from FPGA2 to FPGA1 fail (when ON)

LED4

LED8

DDR status2*

*refer to Table 16: DDR status1-2

Table 16: DDR Status1-2

DDR status1

DDR status2

Description

OFF

OFF

no errors

OFF

ON

Incorrect SO-DIMM module for the test (SPD parameters not valid)

ON

OFF

Calibration failed

ON

ON

Data error present

Table 17: Default S2 DIP Switch Settings for FPGA2 Test

POS1

POS2

POS3

POS4

POS5

POS6

POS7

POS8

OFF

OFF

OFF

ON

ON

OFF

OFF

OFF

Table 18: Default LED1-8 bar LEDs statuses for FPGA2 Test

State

LED

State

BLINK

LED1

LED5

OFF

OFF

LED2

LED6

OFF

OFF

LED3

LED7

OFF

OFF

LED4

LED8

OFF

=H2 LED1-8 Bar LEDs Statuses for FPGA2

Table 19: Bar LEDs status for FPGA1 (POS3, POS4, POS5=ON, OFF, ON)

Description

LED

Description

REF clk present (when BLINK)

LED1

LED5

Empty

Clock test fail (when ON)

LED2

LED6

GTX from FPGA1 to FPGA2 fail (when ON)

Common bus fail (when ON)

LED3

LED7

Empty

LVDS from FPGA1 to FPGA2 fail (when ON)

LED4

LED8

Empty

Table 20: Default S2 DIP Switch Settings for FPGA2 Test

POS1

POS2

POS3

POS4

POS5

POS6

POS7

POS8

OFF

OFF

ON

OFF

ON

OFF

OFF

OFF

Table 21: Default LED1-8 bar LEDs statuses for FPGA2 Test

State

LED

State

BLINK

LED1

LED5

OFF

OFF

LED2

LED6

OFF

OFF

LED3

LED7

OFF

OFF

LED4

LED8

OFF

LED1-8 Bar LEDs Statuses for PLLs Lock Test

Table 22: Bar LEDs status for PLLs Configuration Test (POS3, POS4, POS5=OFF, OFF, ON)

Description

LED

Description

CLK0 PLL locked (when ON)

LED1

LED5

CLK_PLL PLL locked (when ON)

CLK1 PLL locked (when ON)

LED2

LED6

CLK_GTX PLL locked (when ON)

CLK2 PLL locked (when ON)

LED3

LED7

Empty

CLK3 PLL locked (when ON)

LED4

LED8

Empty

Table 23: Default S2 DIP Switch Settings for PLLs Lock Test

POS1

POS2

POS3

POS4

POS5

POS6

POS7

POS8

OFF

OFF

OFF

OFF

ON

OFF

OFF

OFF

Table 24: Default LED1-8 bar LEDs statuses for PLL Lock Test

State

LED

State

ON

LED1

LED5

ON

ON

LED2

LED6

ON

ON

LED3

LED7

OFF

ON

LED4

LED8

OFF

LED1-8 Bar LEDs Statuses for PLLs Configuration Test

Table 25: Bar LEDs status for PLLs Configuration Test (POS3, POS4, POS5=ON, ON, OFF)

Description

LED

Description

CLK0 PLL configuration error (when ON)

LED1

LED5

CLK_PLL PLL configuration error (when ON)

CLK1 PLL configuration error (when ON)

LED2

LED6

CLK_GTX PLL configuration error (when ON)

CLK2 PLL configuration error (when ON)

LED3

LED7

Empty

CLK3 PLL configuration error (when ON)

LED4

LED8

Empty

Table 26: Default S2 DIP Switch Settings for PLLs Configuration Test

POS1

POS2

POS3

POS4

POS5

POS6

POS7

POS8

OFF

OFF

ON

ON

OFF

OFF

OFF

OFF

Table 27: Default LED1-8 bar LEDs statuses for PLL Configuration Test

State

LED

State

OFF

LED1

LED5

OFF

OFF

LED2

LED6

OFF

OFF

LED3

LED7

OFF

OFF

LED4

LED8

OFF

LED1-8 Bar LEDs Statuses for FPGAs done signals

Table 28: Bar LEDs status for FPGAs done signals (POS3, POS4, POS5=OFF, ON, OFF)

Description

LED

Description

FPGA0 Done signal (when ON)

LED1

LED5

Empty

FPGA1 Done signal (when ON)

LED2

LED6

Empty

FPGA2 Done signal (when ON)

LED3

LED7

Empty

Empty

LED4

LED8

Empty

Table 29: Default S2 DIP Switch Settings for FPGAs Done signals

POS1

POS2

POS3

POS4

POS5

POS6

POS7

POS8

OFF

OFF

OFF

ON

OFF

OFF

OFF

OFF

Table 30: Default LED1-8 bar LEDs statuses for FPGAs Done signals

State

LED

State

ON

LED1

LED5

OFF

ON

LED2

LED6

OFF

ON

LED3

LED7

OFF

OFF

LED4

LED8

OFF

Ask Us a Question
x
Ask Us a Question
x
Captcha ImageReload Captcha
Incorrect data entered.
Thank you! Your question has been submitted. Please allow 1-3 business days for someone to respond to your question.
Internal error occurred. Your question was not submitted. Please contact us using Feedback form.
We use cookies to ensure we give you the best user experience and to provide you with content we believe will be of relevance to you. If you continue to use our site, you consent to our use of cookies. A detailed overview on the use of cookies and other website information is located in our Privacy Policy.