« Prev | Next » SW2 DIP Switch and LED1-8 bar LEDs on the HES7XV690-4000BP Board Introduction This application note describes all of the possible configurations of the S2 DIP switch that is available for Diagnostic Design that is delivered with the HES7XV690-4000BP board. The following sections also present status codes that are available on the LED1-8 bar LED indicators. HES7XV690-4000BP S2 DIP switch description Figure 1 S2 DIP Switch location Figure 2 S2 DIP Switch orientation Table 1: S2 DIP Switch Description Table DIP Switch position Function Description POS1 HARD RESET Turning On this switch causes loss of FPGA0-2 configurations POS2 USER RESET Turning ON this switch causes a reset of the user designs in the FPGA0-2 chips POS3 Bar LEDs status selector POS3-5 switches between statuses from FPGA0, FPGA1, FPGA2, PLLs, and the master status from Diagnostic Design POS4 POS5 POS6 PLLs control selector Selects PLLs control master between the USB program and Diagnostic Design POS7 PLLs conf. selector Switches between PLLs configuration type (High/Low speed) that is intended for Diagnostic Design POS8 PLLs Reset PLLs chip reset - must be issued after configuration or PLLs selector change S2 DIP Switch Configuration Tables Table 2: S2 DIP Switch, POS1 Configuration Table POS1 Description ON HARD RESET active - FPGA0-2 lost their configurations OFF (default) HARD RESET inactive - normal operations Table 3: S2 DIP Switch, POS2 Configuration Table POS2 Description ON USER RESET active- reset signal for test design located in FPGA0-2 OFF (default) USER RESET inactive - normal operations Table 4: S2 DIP Switch, POS3-5 Configuration Table POS3 POS4 POS5 Description ON ON ON Eight user statuses from FPGA0 OFF ON ON Eight user statuses from FPGA1 ON OFF ON Eight user statuses from FPGA2 OFF OFF ON Six statuses from PLLs SI5326 - locked signals ON ON OFF Six statuses from I2C configuration module - error NACK signals OFF ON OFF Three statuses of DONE signals from FPGAs OFF OFF OFF Five statuses from Diagnostic Design (default) Table 5: S2 DIP Switch, POS6 Configuration Table POS6 Description ON PLL control from USB program OFF (default) Internal PLL control from Diagnostic Design Table 6: S2 DIP Switch, POS7 Configuration Table POS7 Description ON PLL internal configuration1 – used for High Speed Diagnostic design OFF (default) PLL internal configuration2 – used for Low Speed Diagnostic design Table 7: S2 DIP Switch, POS8 Configuration Table POS8 Description ON PLL Reset active OFF (default) PLL Reset inactive LED1-8 Status Bar LEDs Description Figure 3 LED1-8 status bar LEDs location Figure 4 LED1-8 bar LEDs indicators Diagnostic Design LED1-8 Bar LEDs statuses Table 8: Bar LEDs status for Diagnostic Design Test (POS3, POS4, POS5=OFF, OFF, OFF) Description LED Description Clocking test succeeded (when ON) LED1 LED5 Empty Interconnections test succeeded (when ON) LED2 LED6 Empty GTX/GTH test succeeded (when ON) LED3 LED7 Empty Memory test succeeded (when ON) LED4 LED8 Diagnostic Design is working (when blink) Table 9: Default S2 DIP Switch Settings for Diagnostic Design Test POS1 POS2 POS3 POS4 POS5 POS6 POS7 POS8 OFF OFF OFF OFF OFF OFF OFF OFF Table 10: Default LED1-8 Bar LEDs Statuses for FPGA2 Test State LED State ON LED1 LED5 OFF ON LED2 LED6 OFF ON LED3 LED7 OFF ON LED4 LED8 Blink Diagnostic Design tests description: Memory test - SO-DIM memories test GTX/GTH test - all GTX/GTH connections test Interconnections test - all IO interconnections (all available connections between FPGA0-2) test Clocking test - clock module and clock lines test NOTE: The Diagnostic test takes about 30 seconds and is signalized by the blinking of LED8 LED1-8 Bar LEDs statuses for FPGA0 Table 11: Bar LEDs status for FPGA0 (POS3, POS4, POS5=ON, ON, ON) Description LED Description REF clk present (when BLINK) LED1 LED5 GTX from FPGA1 to FPGA0 fail (when ON) Clock test fail (when ON) LED2 LED6 Empty LVDS from FPGA1 to FPGA0 fail (when ON) LED3 LED7 DDR status1* Common bus fail (when ON) LED4 LED8 DDR status2* *refer to Table 12: DDR status1-2 Table 12: DDR Status1-2 DDR status1 DDR status2 Description OFF OFF no errors OFF ON Incorrect SO-DIMM module for the test (SPD parameters not valid) ON OFF Calibration failed ON ON Data error present Table 13: Default S2 DIP Switch Settings for FPGA0 Test POS1 POS2 POS3 POS4 POS5 POS6 POS7 POS8 OFF OFF ON ON ON OFF OFF OFF Table 14: Default LED1-8 bar LEDs statuses for FPGA2 Test State LED State BLINK LED1 LED5 OFF OFF LED2 LED6 OFF OFF LED3 LED7 OFF OFF LED4 LED8 OFF LED1-8 Bar LEDs Statuses for FPGA1 Table 15: Bar LEDs status for FPGA1 (POS3, POS4, POS5=OFF, ON, ON) Description LED Description REF clk present (when BLINK) LED1 LED5 GTX from FPGA0 to FPGA1 fail (when ON) Clock test fail (when ON) LED2 LED6 GTX from FPGA2 to FPGA1 fail (when ON) LVDS from FPGA0 to FPGA1 fail (when ON) LED3 LED7 DDR status1* LVDS from FPGA2 to FPGA1 fail (when ON) LED4 LED8 DDR status2* *refer to Table 16: DDR status1-2 Table 16: DDR Status1-2 DDR status1 DDR status2 Description OFF OFF no errors OFF ON Incorrect SO-DIMM module for the test (SPD parameters not valid) ON OFF Calibration failed ON ON Data error present Table 17: Default S2 DIP Switch Settings for FPGA2 Test POS1 POS2 POS3 POS4 POS5 POS6 POS7 POS8 OFF OFF OFF ON ON OFF OFF OFF Table 18: Default LED1-8 bar LEDs statuses for FPGA2 Test State LED State BLINK LED1 LED5 OFF OFF LED2 LED6 OFF OFF LED3 LED7 OFF OFF LED4 LED8 OFF =H2 LED1-8 Bar LEDs Statuses for FPGA2 Table 19: Bar LEDs status for FPGA1 (POS3, POS4, POS5=ON, OFF, ON) Description LED Description REF clk present (when BLINK) LED1 LED5 Empty Clock test fail (when ON) LED2 LED6 GTX from FPGA1 to FPGA2 fail (when ON) Common bus fail (when ON) LED3 LED7 Empty LVDS from FPGA1 to FPGA2 fail (when ON) LED4 LED8 Empty Table 20: Default S2 DIP Switch Settings for FPGA2 Test POS1 POS2 POS3 POS4 POS5 POS6 POS7 POS8 OFF OFF ON OFF ON OFF OFF OFF Table 21: Default LED1-8 bar LEDs statuses for FPGA2 Test State LED State BLINK LED1 LED5 OFF OFF LED2 LED6 OFF OFF LED3 LED7 OFF OFF LED4 LED8 OFF LED1-8 Bar LEDs Statuses for PLLs Lock Test Table 22: Bar LEDs status for PLLs Configuration Test (POS3, POS4, POS5=OFF, OFF, ON) Description LED Description CLK0 PLL locked (when ON) LED1 LED5 CLK_PLL PLL locked (when ON) CLK1 PLL locked (when ON) LED2 LED6 CLK_GTX PLL locked (when ON) CLK2 PLL locked (when ON) LED3 LED7 Empty CLK3 PLL locked (when ON) LED4 LED8 Empty Table 23: Default S2 DIP Switch Settings for PLLs Lock Test POS1 POS2 POS3 POS4 POS5 POS6 POS7 POS8 OFF OFF OFF OFF ON OFF OFF OFF Table 24: Default LED1-8 bar LEDs statuses for PLL Lock Test State LED State ON LED1 LED5 ON ON LED2 LED6 ON ON LED3 LED7 OFF ON LED4 LED8 OFF LED1-8 Bar LEDs Statuses for PLLs Configuration Test Table 25: Bar LEDs status for PLLs Configuration Test (POS3, POS4, POS5=ON, ON, OFF) Description LED Description CLK0 PLL configuration error (when ON) LED1 LED5 CLK_PLL PLL configuration error (when ON) CLK1 PLL configuration error (when ON) LED2 LED6 CLK_GTX PLL configuration error (when ON) CLK2 PLL configuration error (when ON) LED3 LED7 Empty CLK3 PLL configuration error (when ON) LED4 LED8 Empty Table 26: Default S2 DIP Switch Settings for PLLs Configuration Test POS1 POS2 POS3 POS4 POS5 POS6 POS7 POS8 OFF OFF ON ON OFF OFF OFF OFF Table 27: Default LED1-8 bar LEDs statuses for PLL Configuration Test State LED State OFF LED1 LED5 OFF OFF LED2 LED6 OFF OFF LED3 LED7 OFF OFF LED4 LED8 OFF LED1-8 Bar LEDs Statuses for FPGAs done signals Table 28: Bar LEDs status for FPGAs done signals (POS3, POS4, POS5=OFF, ON, OFF) Description LED Description FPGA0 Done signal (when ON) LED1 LED5 Empty FPGA1 Done signal (when ON) LED2 LED6 Empty FPGA2 Done signal (when ON) LED3 LED7 Empty Empty LED4 LED8 Empty Table 29: Default S2 DIP Switch Settings for FPGAs Done signals POS1 POS2 POS3 POS4 POS5 POS6 POS7 POS8 OFF OFF OFF ON OFF OFF OFF OFF Table 30: Default LED1-8 bar LEDs statuses for FPGAs Done signals State LED State ON LED1 LED5 OFF ON LED2 LED6 OFF ON LED3 LED7 OFF OFF LED4 LED8 OFF Previous article Next article