Warning: KERNEL_0085 <signal name> does not have read access. Use switch +access +r for this region

Description

This warning is generated by Active-HDL when some of the signals cannot be displayed in the waveform.

Solution

To get internal signal visibility, you have to set the read access to internal signals.

If you use the GUI:

  1. Go to Design | Settings | Simulation | Access to design objects

  2. Specify the appropriate access for the required signals

  3. Click Apply and then OK

If you use a script or batch mode:

Use the +access +r switch for the asim command. For example:

asim +access +r ...
Ask Us a Question
x
Ask Us a Question
x
Captcha ImageReload Captcha
Incorrect data entered.
Thank you! Your question has been submitted. Please allow 1-3 business days for someone to respond to your question.
Internal error occurred. Your question was not submitted. Please contact us using Feedback form.
We use cookies to ensure we give you the best user experience and to provide you with content we believe will be of relevance to you. If you continue to use our site, you consent to our use of cookies. A detailed overview on the use of cookies and other website information is located in our Privacy Policy.